本文へ移動
cccskills
無料GitHub で公開

matlab-read-medical-data

Read, write, and manipulate medical imaging data (DICOM, NIfTI, NRRD) in MATLAB. Covers Image Processing Toolbox functions (dicomreadVolume, niftiread, dicomContours, dicomanon) and Medical Imaging Toolbox enhanced APIs (medicalVolume, medicalImage, medicalref3d, extractSlice, updateOrientation). Use when reading medical files, listing DICOM series, extracting spatial referencing, changing orientation, working with RT structures, or anonymizing DICOM data. Some features require Medical Imaging Toolbox — see skill body and references for details.

インストール方法を見る

含まれるファイル(7)

  • SKILL.md8.8 KB
  • manifest.yaml523 B
  • references/dicom-anonymization.md3.3 KB
  • references/dicom-rt-workflows.md7.4 KB
  • references/ipt-reading-writing.md4.8 KB
  • references/mit-medical-volume.md7.9 KB
  • references/mit-spatial-referencing.md5.9 KB

SKILL.md(原文)

インストールする前に、エージェントに与えられる指示の中身を確認できます。

Read and Write Medical Data

Read, write, and manipulate medical imaging data in MATLAB. This skill covers both Image Processing Toolbox (IPT) functions and Medical Imaging Toolbox (MIT) enhanced APIs.

When to Use

  • Reading or writing DICOM, NIfTI, or NRRD files
  • Listing DICOM series with dicomCollection
  • Extracting spatial referencing or coordinate transforms
  • Changing volume orientation or extracting oriented slices
  • Working with DICOM RT structures (contours, masks, modify/write)
  • Anonymizing DICOM data

When NOT to Use

  • Displaying or visualizing volumes (use matlab-display-volume skill)
  • Displaying 2-D medical images with annotations (use matlab-display-image skill)
  • Reading non-medical image formats (PNG, TIFF, JPEG) — use imread

Toolbox Detection — CRITICAL FIRST STEP

Always check which toolboxes are available before choosing an approach. If Medical Imaging Toolbox is installed, prefer its APIs. If only Image Processing Toolbox is available, use IPT patterns.

Task → Function Quick Reference

TaskIPT onlyWith Medical Imaging Toolbox (preferred)
Read single DICOM filedicomread + dicominfomedicalImage
Read DICOM folderdicomreadVolumemedicalVolume
Read NIfTIniftiread + niftiinfomedicalVolume
Read NRRD— (requires MIT)medicalVolume or nrrdread + nrrdinfo
List DICOM seriesdicomCollectiondicomCollection
Spatial referencingimref3dmedicalref3d
Extract oriented sliceManual indexingextractSlice
Change orientationManual permuteupdateOrientation
Read DICOM RT structuredicomContours(dicominfo(file))Same
Anonymize DICOMdicomanon + dicomuidSame
Visualize volumevolumeViewermedicalVolumeViewer or volshow(medVol)

Top 4 Patterns

1. Read DICOM folder

Call medicalVolume or dicomreadVolume directly on the DICOM folder path. Do NOT call dicomCollection first — it is unnecessary when reading a single-series folder.

% WITH Medical Imaging Toolbox (preferred):
medVol = medicalVolume("path/to/dicom/folder");
V = medVol.Voxels;               % Auto-rescaled (e.g., HU for CT)
spacing = medVol.VoxelSpacing;   % [dx dy dz] in mm
orientation = medVol.Orientation; % "transverse", "coronal", "sagittal"
modality = medVol.Modality;       % "CT", "MR"

% Access spatial referencing via VolumeGeometry (medicalref3d object)
geom = medVol.VolumeGeometry;
geom.VolumeSize;                  % [rows cols slices]
geom.PatientCoordinateSystem;     % "LPS+" or "RAS+"
geom.Position;                    % [slices×3] slice positions in patient coords
geom.VoxelDistances;              % {[slices×3] [slices×3] [slices×3]} per-axis distances
geom.PixelSpacing;                % [slices×2] in-plane pixel spacing per slice
geom.IsAffine;                    % true if uniform spacing (affine transform)
geom.IsAxesAligned;               % true if volume axes align with patient axes
geom.IsMixed;                     % true if slices have varying pixel spacing

% IPT only:
[V, spatial, dim] = dicomreadVolume("path/to/dicom/folder");
V = squeeze(V);  % Remove singleton 4th dimension

2. Read NIfTI file

% WITH Medical Imaging Toolbox (preferred):
medVol = medicalVolume("path/to/file.nii.gz");

% IPT only:
V = niftiread("path/to/file.nii.gz");
info = niftiinfo("path/to/file.nii.gz");
voxelSize = info.PixelDimensions(1:3);

3. List DICOM series and read one

Use dicomCollection only when:

  • The user says the folder contains multiple series or volumes
  • medicalVolume or dicomreadVolume fails with an error (e.g., "not a DICOM file" or "multiple volumes detected")
  • You need to identify what series exist before deciding which one to read

dicomCollection scans the directory, excludes non-DICOM files, and returns a table where each row is one series. It does not read pixel data.

collection = dicomCollection("path/to/directory");
disp(collection);  % Table with Modality, SeriesDescription, Rows, Columns, Frames

% WITH Medical Imaging Toolbox:
medVol = medicalVolume(collection, "s1");

% IPT only:
[V, spatial] = dicomreadVolume(collection, "s1");

4. Extract slice / change orientation (Requires Medical Imaging Toolbox)

medVol = medicalVolume("path/to/file.nii");

% Extract slices — works for any orientation
[axialSlice, position, spacings] = extractSlice(medVol, 50, "transverse");
[coronalSlice, ~, ~] = extractSlice(medVol, 30, "coronal");
[sagittalSlice, ~, ~] = extractSlice(medVol, 45, "sagittal");

% If medVol.Orientation is not empty, use it as the third input
[sliceData, position, spacings] = extractSlice(medVol, 50, medVol.Orientation);

% Change orientation — do NOT use permute
medVolCoronal = updateOrientation(medVol, "coronal");  % Returns NEW object

updateOrientation was introduced in R2025a.

Detailed Reference Files

IMPORTANT: Before generating code for any task below, read the matching reference file first.

Task triggerReferenceRead BEFORE
Reading/writing DICOM or NIfTI with IPTreferences/ipt-reading-writing.mdWriting dicomreadVolume, niftiread, imref3d, or rescale logic
Using medicalVolume, medicalImage, slices, or orientationreferences/mit-medical-volume.mdWriting medicalImage, medicalVolume, extractSlice, or updateOrientation calls
Spatial referencing or coordinate transformsreferences/mit-spatial-referencing.mdWriting medicalref3d, intrinsicToWorld, or worldToIntrinsic calls
RT structures (contours, labelmaps, RTSTRUCT)references/dicom-rt-workflows.mdReading, editing, displaying, or plotting contours/RTSTRUCT files, or writing any dicomContours, plotContour, createMask, addContour, deleteContour call
Anonymizing DICOM filesreferences/dicom-anonymization.mdWriting any dicomanon or dicomuid call

Legacy Patterns to Avoid

Do NOT useUse insteadWhy
dicomread + dicominfo for single filemedicalImage (MIT)Unified access, auto-rescale
dicomreadVolume for DICOM foldermedicalVolume (MIT)Preserves spatial referencing
niftiread + niftiinfomedicalVolume (MIT)Unified container
V.Voxels(:,:,n) or V(:,:,n) for slice extractionextractSlice(medVol, n, medVol.Orientation) (MIT)Handles orientation, spatial metadata, works regardless of storage order
Manual permute for orientationupdateOrientation(medVol, orient) (MIT)Updates spatial metadata
Manual struct parsing for RTdicomContours(info)Clean tabular output
volumeViewermedicalVolumeViewer (MIT, R2026a)Medical-specific features
imshow for medical imagesimageshowBetter defaults for medical data

Conventions

  • Always detect available toolboxes before choosing functions
  • Prefer Medical Imaging Toolbox APIs (medicalVolume, medicalImage) when available
  • Always capture output from immutable methods (deleteContour, updateOrientation)
  • Always use CreateMode="Copy" when writing RT Structure DICOM files
  • Do NOT call dicomCollection before medicalVolume/dicomreadVolume by default — call the reader directly on the folder path
  • Use dicomCollection only when: the folder contains multiple series, medicalVolume fails with an error, or you need to identify what series exist without reading pixel data
  • Always squeeze the output of dicomreadVolume for grayscale data
  • Always use extractSlice to get slices from a medicalVolume — never use V.Voxels(:,:,n) manual indexing. extractSlice handles orientation, spatial metadata, and works correctly regardless of how the volume is stored on disk
  • Never manually parse nested DICOM structs — use dicomContours
  • extractSlice argument order: (vol, sliceIndex, direction) — numeric before string
  • intrinsicToWorld returns 3 separate outputs: [x, y, z] — not a single vector

Copyright 2026 The MathWorks, Inc.


レビュー

まだレビューはありません。使ってみた感想をお寄せください。

同じリポジトリのスキル

概要と使いどころ

Guide for accessing financial and economic data in MATLAB using the Datafeed Toolbox. Covers Bloomberg (market data via bloomberg/blp/bloombergHypermedia), FRED (Federal Reserve economic data via fredrs), Haver Analytics (economic data via haver/haverdirect/haverview), and LSEG Datastream (historical data via datastreamws). Use when connecting to any of these data providers from MATLAB.

日本語の概要は準備中です。原文の説明を表示しています。

matlab/matlab-agentic-toolkit1,1512026年10月9日 更新

Read BEFORE writing any code that adds Additive White Gaussian Noise (AWGN) to signals and converts between SNR, Eb/No, Es/No, and per-subcarrier SNR for communications simulations, using awgn(), convertSNR(), berawgn(). The default MATLAB patterns for AWGN (e.g., 'measured' option, manual SNR formulas) produce subtly incorrect results. This skill specifies the correct calling conventions, required function usage, and critical anti-patterns that must be avoided.

日本語の概要は準備中です。原文の説明を表示しています。

matlab/matlab-agentic-toolkit1,1512026年10月9日 更新

Analyze AMS waveform data using Mixed-Signal Blockset utilities: phase noise measurement, clock jitter, anti-aliased resampling, timing measurements, lock time, INL/DNL, ADC/DAC calibration, HSpice import. Use when analyzing time-domain voltage from PLL/VCO/clock simulations, measuring phase noise from variable-step solver output, computing jitter, or resampling non-uniform data.

日本語の概要は準備中です。原文の説明を表示しています。

matlab/matlab-agentic-toolkit1,1512026年10月9日 更新

Design and analyze electrically large antenna structures using MATLAB Antenna Toolbox. Covers reflector antennas (parabolic, Cassegrain, Gregorian, offset, corner, cylindrical, spherical, custom STL), reflectarrays and reconfigurable intelligent surfaces (RIS), antennas installed on platforms (vehicles, aircraft, ships, satellites), and radar cross section (RCS) analysis. Includes solver selection (MoM-PO, PO, MoM, FMM), mesh control, and GPU acceleration. Use when the user wants to design a dish/reflector antenna, reflectarray, analyze an antenna on a platform, or compute RCS.

日本語の概要は準備中です。原文の説明を表示しています。

matlab/matlab-agentic-toolkit1,1512026年10月9日 更新

Analyze data using MATLAB. Use when the task involves tables, timetables, time-series data, numeric arrays, sensor matrices, or gridded data — including but not limited to exploring, row filtering, sorting, cleaning, transforming, aggregating, smoothing, padding, trimming, and answering questions about data. MATLAB provides extensive, easy-to-use built-in functions for these workflows with no additional products required.

日本語の概要は準備中です。原文の説明を表示しています。

matlab/matlab-agentic-toolkit1,1512026年10月9日 更新

S-parameters, insertion loss, fields, currents, mesh control, and solver selection for RF PCB performance validation. TRIGGER: user asks to compute S-parameters, analyze insertion/return loss, extract fields or currents, compare MoM vs FEM, or control mesh for any RF PCB component. Invoke BEFORE writing sparameters() or solver code — API is non-obvious. SKIP: designing or creating components (use the specific matlab-design-pcb-* skill), material/stackup setup only (use matlab-manage-pcb-material), optimization sweeps (use matlab-optimize-pcb-design), PDN/IR-drop analysis (use matlab-analyze-pcb-pdn).

日本語の概要は準備中です。原文の説明を表示しています。

matlab/matlab-agentic-toolkit1,1512026年10月9日 更新

matlab のスキルをすべて見る