Perform various data analysis on SEC 13-F and obtain some insights of fund activities such as number of holdings, AUM, and change of holdings between two quarters.
日本語の概要は準備中です。原文の説明を表示しています。
Use this skill when implementing PID control loops for adaptive cruise control, vehicle speed regulation, throttle/brake management, or any feedback control system requiring proportional-integral-derivative control.
インストール方法を見るインストールする前に、エージェントに与えられる指示の中身を確認できます。
A PID (Proportional-Integral-Derivative) controller is a feedback control mechanism used in industrial control systems. It continuously calculates an error value and applies a correction based on proportional, integral, and derivative terms.
output = Kp * error + Ki * integral(error) + Kd * derivative(error)
Where:
error = setpoint - measured_valueKp = proportional gain (reacts to current error)Ki = integral gain (reacts to accumulated error)Kd = derivative gain (reacts to rate of change)class PIDController:
def __init__(self, kp, ki, kd, output_min=None, output_max=None):
self.kp = kp
self.ki = ki
self.kd = kd
self.output_min = output_min
self.output_max = output_max
self.integral = 0.0
self.prev_error = 0.0
def reset(self):
"""Clear controller state."""
self.integral = 0.0
self.prev_error = 0.0
def compute(self, error, dt):
"""Compute control output given error and timestep."""
# Proportional term
p_term = self.kp * error
# Integral term
self.integral += error * dt
i_term = self.ki * self.integral
# Derivative term
derivative = (error - self.prev_error) / dt if dt > 0 else 0.0
d_term = self.kd * derivative
self.prev_error = error
# Total output
output = p_term + i_term + d_term
# Output clamping (optional)
if self.output_min is not None:
output = max(output, self.output_min)
if self.output_max is not None:
output = min(output, self.output_max)
return output
Integral windup occurs when output saturates but integral keeps accumulating. Solutions:
Manual Tuning:
Effect of Each Gain:
まだレビューはありません。使ってみた感想をお寄せください。
概要と使いどころ
Perform various data analysis on SEC 13-F and obtain some insights of fund activities such as number of holdings, AUM, and change of holdings between two quarters.
日本語の概要は準備中です。原文の説明を表示しています。
AC branch pi-model power flow equations (P/Q and |S|) with transformer tap ratio and phase shift, matching `acopf-math-model.md` and MATPOWER branch fields. Use when computing branch flows in either direction, aggregating bus injections for nodal balance, checking MVA (rateA) limits, computing branch loading %, or debugging sign/units issues in AC power flow.
日本語の概要は準備中です。原文の説明を表示しています。
Redact text from PDF documents for blind review anonymization
日本語の概要は準備中です。原文の説明を表示しています。
Use when checking simplified ADA-derived plan-view bathroom accessibility constraints such as turning space, door clear width, toilet centerline, grab bars, and lavatory knee/toe clearance.
日本語の概要は準備中です。原文の説明を表示しています。
Analyze failed GitHub Action jobs for a pull request.
日本語の概要は準備中です。原文の説明を表示しています。
Use when extracting plan-view architectural geometry from DXF files with semantic CAD layers, especially when outputs must normalize rooms, doors, fixtures, clearances, and grab bars into machine-checkable JSON.
日本語の概要は準備中です。原文の説明を表示しています。